DIN 4102-1 fire test to building material-classification
-
Post Date:
Aug 01,2014
-
Expiry Date:
Aug 01,2015
-
Detailed Description:
DIN 4102-1 fire test to building material-classification
Firetc fire test center will provide Germany Standard DIN 4102-1 Fire test to Building Material.
For more detailed information about DIN 4102-1,
Please see: http://www.firetc.net/firetesting/show.php?itemid=663
DIN 4102-1 fire test to building material
> DIN 4102-1 Fire behaviour of building materials and elements Part 1: Classification of building materials Requirements and testing
DIN 4102-1 fire test to building material - Instruction
This standard defines fire behaviour classes for building materials and specifies requirements and test methods for each class
> DIN 4102-1 fire test to building material - Classification
When the material's fire behaviour has been determined in accordance with the standard, it divides into:
> DIN 4102-1: Class A
A1: Materials may be classed as A1 materials if they:
- Pass the test specified according the standard corresponding parts
- meet the requirements for class A2 materials
A2: Materials may be classed as A2 materials if they:
- Pass the test specified according the standard corresponding parts
- Pass the test specified DIN 4102-16
> DIN 4102-1: Class B
B1: All materials, except flooring, may be classed as B1 materials if they
- Withstand the test specified in DIN 4102-16 using the”Brandschacht” apparatus specified in DIN 4102-15
- Meet the requirements for class B2 materials.
B2: Materials may be classed as B2 materials if they
- Pass the test specified according the standard corresponding parts
- Flooring materials may be assigned to material class B2 if they meet at least the requirements for class T-b as in DIN 66081.
B3: Combustible materials which cannot be classed as B1 or B2 materials shall be classed as B3 materials
DIN 4102-1 fire test to building material - Reference Standard
> DIN 4102-2: Fire behaviour of building materials and elements - Building components - Concepts, requirements and tests
> DIN 4102-4: Fire behaviour of building materials and elements - Overview and design of classified building materials, elements and components
> DIN 4102-8: Fire behaviour of building materials and elements - Small-scale test furnace
> DIN 4102-14: Fire behaviour of building materials and elements - Determination of the burning behaviour of floor covering systems using a radiant heat source
> DIN 4102-15: Fire behaviour of building materials and elements - ‘Brandschacht’ apparatus
> DIN 4102-16: Fire behaviour of building materials and elements - ‘Brandschacht’ tests
> DIN 18180: Gypsum plasterboard - Types, requirements and testing
> DIN 50014: Artificial climates in technical applications - Standard atmospheres
> DIN 50050-1: Small cabinets for testing the burning behaviour of materials
> DIN 50051 Burners for testing the burning behaviour of materials
> DIN 50055 Light measuring system for testing smoke development
> DIN 51622 Propane, propene, butane, butene and their mixtures – Requirements
> DIN 51900-2 Determination of gross calorific value of solid and liquid fuels using the bomb calorimeter, and calculation of calorific value - Method using the isothermal
> DIN 51900-3 Determination of gross calorific value of solid and liquid fuels using the bomb calorimeter, and calculation of calorific value - Method using the adiabatic
> DIN 53436-1: Toxicity testing of fire effluents - Combustion apparatus and determination of test temperature
> DIN 53436-2: Toxicity testing of fire effluents - Thermal decomposition method
> DIN 53436-3: Toxicity testing of fire effluents - Method of testing inhalation toxicity
> DIN 53438-1: Determining the response of combustible materials to ignition by a small flame – General
> DIN 66081: Classification of the burning behaviour of textile products - Textile floor coverings
> IS0 1716: 1973 Building materials - Determination of calorific potential
> IS0 4783-2: 1989 Industrial wire screens and woven wire cloth - Guide to the choice of aperture size and wire diameter combinations - Part 2: Preferred combinations for woven wire cloth
DIN 4102-1 fire test to building material-Similar standard
> EN ISO 11925-2: Reaction to fire tests--Ignitability of building products subjected to direct impingement of flame--Part 2: Single-flame source test
> EN 13501-1: Fire classification of construction products and building elements- Part1: Classification using data from reaction to fire tests
> NF P 92 - 501: Safety against fire - Building materials - Reaction to fire tests - Radiation test used for rigid materials. or for materials on rigid substrates (flooring and finishes) of all thicknesses. and for flexible materials thicker that 5 mm
> NF P 92 - 503: Safety against fire - Building materials--Reaction to fire tests. Electrical burner test used for flexible materials
> BS 476: Fire tests on building materials and structures
> GB 8624: Classification for burning behavior of building materials and products
> GB 20286: Requirements and mark on burning behavior of fire retarding products and subassemblies in public place
For more detailed information about Germany Standard DIN 4102-1 fire test to Building Material. Please contact on firetest@firetc.com.
Learn more from www.firetc.net for English or www.firetc.com for Chinese
-
Company:
Firetc Fire Test Center
[ China ]
-
Contact:
Liu
-
Tel:
0592-5056213
-
Fax:
0592-5105807
-
Email:
firetest@firetc.com
Inquiry