Offter to Sell

ST350 2M Tester

  • Post Date:

    May 28,2013
  • Expiry Date:

    May 28,2014
  • Detailed Description:

    Cas No. :ST350 Payment Method: TT, Western Union, Paypal
    2M Transmission Analyzers is mainly used for measuring of the error rate of data communication and for the analysis of line fault and causes, and very suitable for the parameter measurement and routine maintenance testing of 2M system, NX64K communication channels.

    Major Features
    ●English menu, Large screen, Easy operation.
    ●Multitask operation (It is allowed to conduct a test while browsing
    previous records).
    ●Test results can be stored, and kept in memory in the event of
    power failure.
    ●The instrument can be powered on or off at certain times for testing purpose.
    ●Column diagram analysis of alarms and error codes.
    ●Software updating online

    Major Functions
    ●Service-interrupted error code testing;
    ●Framing and non-framing signals generation and reception;
    ●2 Mbit/s non-framingÿ error code performance testing;
    ●2 Mbit/s framing NX64kbit/s channel error code performance testing;
    ●Performance testing of bit error, coding error, frame error, CRC error and E bit error;
    ●Alarm testing of signal loss, AIS alarm, frame remote alarm, multiframe remote alarm,
    out-of-frame, and out-of-pattern synchronism;
    ●Frequency swing testing;
    ●Through mode;
    ●G. 821/G. 826/M. 2100 error code performance analysis;
    ●Two clock options (internal and picking-up);

    Technical Index
    2M Technical Index
    (1) Signal input rate: 2048kbit/s±100ppm (G.703 requirement±50PPM)
    (2) Signal coding: HDB3, AMI.
    (3) Input jitter tolerance: 10UI 20Hz to 2.4 KHz, 0.5UI 18 to 100HZ
    (4) Input balance response: Attenuation complies with the law of squareÿ root of frequency, and is within the
    range of 0 to 6dB at 1024 kHz.
    (5) Input Impedance
    (5.1) Unbalance terminating: 75W
    Balance terminating: 120W.
    Reflection loss >18dB within 50Hz to 3100 kHz.
    (5.2) Unbalance bridging: > 750W Balance bridging: >1200W
    (5.3) Unbalance monitoring: 75W, 26dB gain
    Balance monitoring: 120W, 26dB gain

    Reflection loss >18dB within 50Hz to 3100kHz.
    (6) Signal structure
    (6.1) Non-frame structure
    (6.2) Frame structure: PCM30, PCM31, PCM30CRC, PCM31CRC
    Frame structure complies with the requirement of G. 704.
    (7) Testing pattern: 2E6-1, 2E9-1, 2E11-1, 2E15-1, 2E20-1,2E23-1and artificial code
    (8) Impedance of output interface:
    (8.1) Non-balance 75W, up to G. 703
    (8.2) Balance 120W, up to G.ÿ 703.
    (9) External clock input
    (9.1) Signal form: HDB3, NRZ
    (9.2) Balance terminating resistance: 120W
    Unbalance terminating resistance: 75W
    Balance bridging resistance: >1200W
    Unbalance bridging resistance :>750W
    (10) Error code insertion: None, single, or ratio 10-1 ~ 10-7.

    Other Parameters
    Power supply: Input: AC220V 50Hz Output: DC 9V 1A
    Internal battery: 1400mAh, 7.2V Li battery
    Working time: More than 4 hours
    Charging time: Less than 2 hours.
    Dimension150X95X42mm
    Weight: 255g
    Operation temperature: 0 to 40℃
    Storage Temperature: -30 to +70℃
    Humidity: 5% to 90%, non-condensing

    Standard Configuration
    1. 2M Transmission Analyzers 1 set
    2. Users manual 1 pcs
    3. 75ohm testing wire 2pcs
    4. Power adapter 1 pcs
    5. Portable bag 1 pcs
  • CAS Registry Number:

    ST350
  • Company:

    Shandong Senter Electronic Co.,Ltd.     [ China ]        
  • Contact:

    Dancing Cui
  • Tel:

    86-533-3589257
  • Fax:

    86-533-3587522
  • Email:

    export@senter.com.cn
Inquiry
Home Suppliers Product CAS Gmall